  1. AGM battery chargers vs normal battery charger? — northernarizona ...

    Re: AGM battery chargers vs normal battery charger? A good place to start is reading the Battery FAQ. Basically, AGM batteries are very sensitive to overcharging vs flooded cell batteries. When you …

  2. What is the normal resting voltage of a fully charged AGM 12V battery?

    I have a number of 12V AGM batteries that I have fully charged and the resting voltage (measured several days after charging was completed with no discharge) ranged from 12.96 to 13.3V.

  3. 48V Inverter/charger vs. MPPT SCC float settings for AGM string

    My XW6048 charger is set to a float voltage of 55.4v for my AGM battery bank (4 cells in series in 2 parallel strings), but the float voltage of my SCC is set to 54.0V by default. Wouldn't that use grid …

  4. Charge batteries from charger and solar at once

    May 1, 2011 · Can you have batteries being charged from a battery charger (Iota) and solar charge controller (Morningstar SunSaver) output at the same time? My battery cable +, charge controller …

  5. oh sheet agm levels at 12 v — northernarizona-windandsun

    I’ve abused a couple of AGM batts and have gotten them back to 95% or so using a smart charger. Here’s a SOC chart: Best of luck with your bank. I find those voltage levels optimistic. 12.8 volts is a …

  6. Charging AGM Batteries from Car Alternator - northernarizona …

    3. Install a charge controller to prevent overcharging (AGM batteries prefer a lower float voltage than starter batteries). My first question is whether it is worth wiring the negative battery terminal all the …

  7. Mission Impossible? Recharging a 2019 AGM 12V battery showing 1.3 …

    2019 AGM 12V starter battery discharged to 1.3 volts. Four modern chargers failed to initiate the charge process. A 1990's 10 amp charger is slowly bringing up the voltage however. It is feeding the battery …

  8. Separate AGM battery charger for RV solar?

    Re: Separate AGM battery charger for RV solar? I don't personally like the Iota for shore power charging, even with it's module. I don't think it really does a true 3 or 4 stage charge. I belive they are …

  9. charging AGM batteries in cold climates - northernarizona-windandsun

    Hello Wind-sun forum, I have a question regarding care of AGM batteries in cold climates. My situation is that I am leaving my cabin for a few days to a week unheated in below 0 temps (down to -20C …

  10. AGM Trickle CHarger - northernarizona-windandsun

    I have a 55W panel charging the battery through a Tristar charge controller. I need to supplement the system w/ some battery charging, and was looking for an inexpensive AGM trickle charger.